BOD Measuring system OxiTop®-IDS for determination of biogas/microbiology
For the measurement of anaerobic degradability with OxiTop®-IDS/B measuring heads. The main application for these sets is the testing of fermentability of biological waste for biogas plants acc. to VDI 4630. The yield of methane can be measured in the pressure mode.
With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.
-Convenient and safe operation within an extended pressure range of up to 1500 hPa
-Pressure range excess warning
-Corrosion-proof head even in presence of H2S
-Bluetooth® connectivity
-Direct calculation of all results in the meter
-Representation of curves for monitoring
-Parallel measurement of different examinations and methods
-Export to data acquisition programs
Scope of supply:
OxiTop®-IDS AN6: 6 x OxiTop®-IDS/B measuring heads, 6 sample bottles MF45/1000 (1000 ml), nitrification inhibitor, 6 x magnetic stirring bars, stirring bar retriever, 1 stirring platform IS 6-Var
OxiTop®-IDS AN12: 12 x OxiTop®-IDS/B measuring heads, 12 sample bottles MF45/250 (250 ml), nitrification inhibitor, 12 x magnetic stirring bars, stirring bar retriever, 1 stirring platform IS-12
Please order CO2 absorber NHP 600 (9.303 403) separately.
The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.
With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.
-Convenient and safe operation within an extended pressure range of up to 1500 hPa
-Pressure range excess warning
-Corrosion-proof head even in presence of H2S
-Bluetooth® connectivity
-Direct calculation of all results in the meter
-Representation of curves for monitoring
-Parallel measurement of different examinations and methods
-Export to data acquisition programs
Scope of supply:
OxiTop®-IDS AN6: 6 x OxiTop®-IDS/B measuring heads, 6 sample bottles MF45/1000 (1000 ml), nitrification inhibitor, 6 x magnetic stirring bars, stirring bar retriever, 1 stirring platform IS 6-Var
OxiTop®-IDS AN12: 12 x OxiTop®-IDS/B measuring heads, 12 sample bottles MF45/250 (250 ml), nitrification inhibitor, 12 x magnetic stirring bars, stirring bar retriever, 1 stirring platform IS-12
Please order CO2 absorber NHP 600 (9.303 403) separately.
The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.
| Pressure: | 500 ... 1,500 hPa |
| Measured range: | 0 ... 4,000 mg/l |
| Measuring time: | 180 d |
| Power supply: | 100 ... 240 V, 50/60 Hz |
Item added to basket.
BOD Measuring system OxiTop®-IDS for determination of biogas/microbiology
TypeNo. of measuring
positionsNominal volume bottle
positionsNominal volume bottle
ml
PKPrice/UnitEUR

TypeOxiTop®-IDS AN6
No. of measuring
positions6
Nominal volume bottle
ml
1000ml
PK1
1 VE6.323,00
€
EUR7.524,37€
EUR incl. Taxplease selectAdd to
basket
basket
Code: 6.314 045
not in stock
TypeOxiTop®-IDS AN12
No. of measuring
positions12
Nominal volume bottle
ml
250ml
PK1
1 VE10.501,00
€
EUR12.496,19€
EUR incl. Taxplease selectAdd to
basket
basket