Multi meters Portavo 907 Multi
The only portable device for all Memosens parameters. Also for conventional analog sensors. The powerful Li-ion battery can be charged in the device via USB. The clear network diagram provides an at-a-glance view of the sensor condition.
The following logging types can be selected:
The data logger for up to 10,000 entries records point of measurement, annotation, sensor ID, sensor serial number (Memosens), primary value, temperature, time stamp, and device status.
User-friendly software
Portavo 907 proves that a high level of functionality and easy use are not mutually exclusive. It proceeds step by step through the calibration procedure. Technical terms are clearly explained in the context-sensitive help.
The following logging types can be selected:
- Manual logging
- Time-controlled logging at a fixed interval
- Signal-controlled logging of measured value and temperature
- Combined time and signal-controlled logging
- Threshold-controlled logging with pre-trigger
The data logger for up to 10,000 entries records point of measurement, annotation, sensor ID, sensor serial number (Memosens), primary value, temperature, time stamp, and device status.
User-friendly software
Portavo 907 proves that a high level of functionality and easy use are not mutually exclusive. It proceeds step by step through the calibration procedure. Technical terms are clearly explained in the context-sensitive help.
- High-resolution color graphic display
- Transflective and sunlight readable
- Li-ion battery
- Micro USB port and Paraly SW 112 software
- A sensor quiver protects the sensor from damage and drying out
- The high-performance polymer housing ensures low water absorption and high impact resistance
- Intelligent data logger with 10,000 entries and graphical representation
- Memosens sensors and analog pH sensors can be used on one device (e.g. flat-membrane sensors)
- The mineral glass display is perfectly readable even after years
Specifications | |
pH/mV input (analogue): pH: mV: | -2 to 16 (<0.01) -1300 to 1300 (<1% meas. val.,<0.3mV/K) |
Temperature input: Temperature with NTC 30 kO: Temperature with Pt 1000: | -20 to +120°C (<0.2K) -40 to +250°C (<0.2K) |
Memosens input (ISFET): pH: mV: Temperature range: | -2.000 to +16.000 (<0.01) -2000 to +2000 (<1% meas. val.,<0.3mV/K) -50 to +250°C (<0,2K) |
Memosens input, Redox: mV: Temperature range: | -2000 to +2000 (<1% meas. val.,<0.3mV/K) -50 to +250 °C (<0.2K) |
Conductivity measuring range: | 0.001µS/cm (c<0.05cm-1) 0.01µS/cm (c=0.05 to 0.2cm-1) 0.1µS/cm (c>0.2cm-1) |
TDS: Salinity: Resistivity: Concentration: | 0 to 1999mg/l 0.0 to 45.0g/kg 00.00 to 99.99MO x cm 0.00 to 9.99 (w/w) % |
Conductivity input (analogue): Measuring range with | |
Sensor SE 202: Sensor SE 204: 2-electrode sensors: 4-electrode sensors: | 0.01 to 200µS/cm 1µS/cm to 500mS/cm 0.1µS x c to 200mS x c 0.1µS x c to 1000mS x c |
Temperature input: Measuring range with NTC 30 kO: Measuring range with Pt 1000: | -20 to +120°C -40 to +250°C |
Conductivity input, Memosens: Measuring range Sensor SE 215 MS: | 10µS/cm to 20mS/cm |
Conductivity input: Temperature compensation: nLF: | Linear 0 to 20%/K, ref. temp. adjustable 0 to 120 °C |
Memosens input, oxygen (optical): Saturation: Concentration: | 0.000 to 1000.0% 000µg/l to 100.00mg/l |
Partial pressure: Temperature measuring range: | 0.0 to 2000mbar -20 to+150°C |
Power supply: IP code acc. to DIN EN 60529: | 4 x AA IP66/67 with pressure compensation |
Topseller
Safety pipette bulb, rubber, red
from 9,65 €
Magnetic stirrer IKA Plate (RCT digital)
from 1.172,00 €
TypeDescriptionPKPrice/Unit
EUR
907 Multi pHCode: 9.774 720 not in stockone additional input for analogue pH mesurements11.310,00
basket
€
1.558,90€
incl. Tax Add tobasket
907 Multi CondCode: 9.774 717 not in stockone additional input for analogue conductivity mesurements11.464,00
basket
€
1.742,16€
incl. Tax Add tobasket
907 Multi OxyCode: 9.774 718 not in stockone additional input for analogue/optical oxygen mesurements11.510,00
basket
€
1.796,90€
incl. Tax Add tobasket
Code: 9.774 720 not in stock
Type907 Multi pH
Descriptionone additional input for analogue pH mesurements
PK1
1 VE1.310,00
€
EUR1.558,90€
EUR incl. Taxplease selectAdd to
basket
basket
Code: 9.774 717 not in stock
Type907 Multi Cond
Descriptionone additional input for analogue conductivity mesurements
PK1
1 VE1.464,00
€
EUR1.742,16€
EUR incl. Taxplease selectAdd to
basket
basket
Code: 9.774 718 not in stock
Type907 Multi Oxy
Descriptionone additional input for analogue/optical oxygen mesurements
PK1
1 VE1.510,00
€
EUR1.796,90€
EUR incl. Taxplease selectAdd to
basket
basket